://Empty Flash Columns

Empty Flash Columns

Empty Flash Column
Weight: 4g, 12g , 25g, 40g, 60g, 80g, 100g, 120g, 220g, 330g
Surface pH: 6.3-7.2
Length: 115.1, 137.8, 188.2, 188.7, 173.3, 263.5, 146.6, 277.7, 218.5, 271.6

Category:

Description

Flash-Columns

Description of Empty Flash Columns

Hawach Empty flash column (solid load cartridges ) are perfect for application of insoluble samples purification.
Available in size from 4gram to 330gram, all cartridge made from medical grade PP material and with standard Luer lock connection fittings, it can make sure fitting with most of the flash systems.

Advantage of Empty Flash Columns

The available prepacked or empty column to different customer need
Reusable flash column between batches
Quickly remove solvents from solid load cartridges
The column can be compatible with all normal and reversed-phase solvents.
Loading insertion rod (packing tool of empty columns) available
Full range of column size available for a different need, purifying from milligrams to several grams
The column can help realize perfect peak shape and performance for both acidic and basic compounds

HPLC-UV Test of Extractable Species for Empty Flash PP Cartridge and PE Frit

Experiment Purpose:

Flash column are commonly used in lab separation of mixture species, the most import properties for the flash column are separation efficiency and low extraction blank level, this experiment is aimed to confirm that Hawach empty flash PP Cartridge and PE frit have no extractable species which could be tested by HPLC-UV.

Experiment Process:

Fill the empty flash column with 6 ml HPLC grade methanol, methanol/dichloromethane(3:1) mixture solution, and petroleum ether/ethyl acetate(1:1) separately for 24 h, and then test the extraction solvents by HPLC-UV.

HPLC-UV Parameters

Column : C18:250*4.6 mm
Flow rate: 1mL/min
Wavelength: 220 nm
Injection Volume: 20 μL
Temperature: 40°C
Analysis Time: 45 min
Mobile Phases: A) Acetonitrile B) Water

Gradient:

Hold 60% A for 10 min
60% to 95% A in 20 min
95% to 100% A in 10 min

Experiment Results:

As shown in the figure below, we can see that all the curve of extraction solvents has the same shape with that of the blank solvents, and there is no other peaks appeared, meaning that no extractable impurities of Hawach flash column.

Empty Flash Columns2Empty Flash Columns3

Technical Data

Item No.  50μm-75μm
Surface pH 6.3-7.2
Water Content 3.0-5.0%

Ordering Information

Item   No.  Description Package(pcs/pk)
SLEP0004PF 4g empty solid load cartridge with screw cap, frits, tips and O-ring optional
SLEP0012PF 12g empty solid load cartridge with screw cap, frits, tips and O-ring optional
SLEP0025PF 25g empty solid load cartridge with screw cap, frits, tips and O-ring optional
SLEP0040PF 40g empty solid load cartridge with screw cap, frits, disbursing unit, tips and O-ring optional
SLEP0080PF 80g empty solid load cartridge with screw cap, frits, disbursing unit, tips and O-ring optional
SLEP0120PF 120g empty solid load cartridge with screw cap, frits, disbursing unit, tips and O-ring optional
SLEP0220PF 220g empty solid load cartridge with screw cap, frits, disbursing unit, tips and O-ring optional
SLEP0330PF 330g empty solid load cartridge with screw cap, frits, disbursing unit, tips and O-ring optional